Comparative evaluation of bispectral index and hemodynamic changes during induction of anaesthesia with propofol and thiopentone

Authors

  • Muralidhar Anakapalli Department of Anesthesia, Ahalia Medical Group, Abu Dhabi, United Arab Emirates
  • Hanumantha Rao Mangu Department of Anesthesia, AIIMS, Madurai, Tamil Nadu, India
  • Pawan B. Nanaiah Department of Orthopedic Surgery, Ahalia Medical Group, Musaffah, Abu Dhabi, United Arab Emirates
  • Arulmurugan Balasubramanian Department of Anesthesia, Phoenix Hospital, Abu Dhabi, United Arab Emirates
  • Hari Ramachandran Nair Department of Anesthesia, Ahalia Medical Group, Abu Dhabi, United Arab Emirates
  • Avinash Maheswarappa Department of Anesthesia, Ahalia Medical Group, Abu Dhabi, United Arab Emirates

DOI:

https://doi.org/10.18203/2319-2003.ijbcp20261944

Keywords:

Bispectral index, Propofol, Thiopentone, Induction of anaesthesia, Hemodynamic changes, Intubation, General anaesthesia

Abstract

Background: Induction requires sufficient anaesthetic depth to prevent patient awareness while maintaining hemodynamic stability. The research study used Bispectral index (BIS) measurements to test the effectiveness of thiopentone and propofol as general anaesthesia induction agents.

Methods: A randomised prospective trial with masked members of the study overcame the logistical issues of recruiting 60 ASA I patients of between18-65 years of age for consecutive first time surgical procedures, with all patients recruited on a non first case basis. The 60 patients were placed randomly into two groups for receiving either thiopentone 5 mg/kg (Group T) or propofol 2 mg/kg (Group P) as their induction agents. The study was conducted for 600 seconds with the first data collection point being at the start of the procedure (0) and at 24 seconds after induction, including BIS measurements along with heart rates and mean arterial pressure.

Results: BIS values were found to decrease following propofol use by a total of 33.7±7.43 while thiopentone was 44.8±10.61. The total duration of a BIS<60 was greater for propofol than thiopentone (190.13±91.0 seconds versus 70.53±41.3 seconds). At 240 seconds post administration, propofol BIS was 43.9±15.12 and thiopentone was 65±6.8. It was also determined that thiopentone provided better hemodynamic stability since it caused very little decrease in mean arterial pressure or heart rate.

Conclusions: Propofol was better than thiopentone in preserving sufficient hypnotic depth during induction and intubation, but thiopentone had better hemodynamic stability.

References

Mathur S, Patel J, Goldstein S, Joseph Maxwell H, Ankit J. Bispectral Index. Stat Pearls. 2026.

Gu Y, Hao J, Wang J, Liang P, Peng X, Qin X, et al. Effectiveness assessment of bispectral index monitoring compared with conventional monitoring in general anesthesia: a systematic review and meta-analysis. Anesthesiol Res Pract. 2024;2024:5555481.

Schonberger RB, Dai F, Michel G, Vaughn MT, Burg MM, Mathis M, et al. Association of propofol induction dose and severe pre-incision hypotension among surgical patients over age 65. J Clin Anesth. 2022;80:110846.

Cheriyan T, Bai K, Bayyapureddy S, Dua A, Singh P, Sun Z, et al. Effect of bispectral index on intra-operative awareness: a meta-analysis of randomized controlled studies. Saudi J Anaesth. 2024;18(3):360-70.

Laferrière-Langlois P, Morisson L, Jeffries S, Duclos C, Espitalier F, Richebé P. Depth of anesthesia and nociception monitoring: current state and vision for 2050. Anesth Analg. 2024;138(2):295-307.

Zou H, Xi F, Fu Y, Xu J, Zhang P, Li D, et al. Bispectral index-monitored anesthesia induction in older adults undergoing elective surgery: comparing ciprofol and propofol in a prospective, single-center, double-blind randomized controlled study. Drug Des Devel Ther. 2024;18:4993-5003.

Sjøen GH, Falk RS, Hauge TH, Tønnessen TI, Langesæter E. Hemodynamic effects of a low versus a high dose of propofol during induction of anesthesia: a randomized trial. Acta Anaesthesiol Scand. 2023;67(9):1178-86.

Yildirim SA, Dogan L, Sarikaya ZT, Ulugol H, Gucyetmez B, Toraman F. Hypotension after anesthesia induction: target-controlled infusion versus manual anesthesia induction of propofol. J Clin Med. 2023;12(16):5280.

Vale AGG, Govêia CS, Guimarães GMN, Terra LR, Ladeira LCA, Essado GA. Comparison of arterial hypotension incidence during general anesthesia induction: target-controlled infusion vs bolus injection of propofol: a randomized clinical trial. Braz J Anesthesiol. 2024;74(4):844503.

Tu Z, Zhang Y, Lv X, Wang Y, Zhang T, Wang J, et al. Accurate machine learning-based monitoring of anesthesia depth with EEG recording. Neurosci Bull. 2025;41(3):449-60.

Li T, Huang Y, Wen P, Li Y. Accurate depth of anesthesia monitoring based on EEG signal complexity and frequency features. Brain Inform. 2024;11(1):28.

Kim HJ, Kim N, Kim J, Park JH, Shin HJ, Yang J, et al. Intraoperative hypotension after remimazolam or propofol induction with sevoflurane maintenance in angiotensin II receptor blockers-treated patients: a randomized controlled trial. Sci Rep. 2025;15:39805.

Zhou C, Wang X, Zhou M, Guo S, Qi Y, Sun J, et al. Comparison of remimazolam and propofol on post-induction hypotension in elderly hypertensive patients: a randomized controlled trial. Drug Des Devel Ther. 2025;19:3425.

Da X, Li X, Dong A, Chen L, Ma Y, Li X. Effect of electroencephalogram-guided anesthesia on postoperative delirium in older adults after surgery: a systematic review and meta-analysis. Front Neurol. 2025;16:1638282.

Downloads

Published

2026-06-23

How to Cite

Anakapalli, M., Mangu, H. R., Nanaiah, P. B., Balasubramanian, A., Nair, H. R., & Maheswarappa, A. (2026). Comparative evaluation of bispectral index and hemodynamic changes during induction of anaesthesia with propofol and thiopentone. International Journal of Basic & Clinical Pharmacology, 15(4), 596–602. https://doi.org/10.18203/2319-2003.ijbcp20261944

Issue

Section

Original Research Articles